SynWire – Winding Wires SynWire W 220, Copper Wire, flat, enamelled
- Enamelled flat copper wire, thermoresistant
- Insulated with polyamide-imide
- Class 220
SynWire W 220 Flat is a highly thermoresistant enamelled copper wire of heat performance class R with superior thermal, chemical and mechanical resistance. It is used for special applications requiring the following criteria:
- very high permanent thermal resistance and short-time thermal overload
- very good resistance to aggressive mediums in liquid or gas form
SynWire W 220 Flat is ideally suited for use in sepcial safety-relevant and electrical life support equipment. Sophisticated process technology and process setting ensure easy mouldabilty, good elongation and constant insulation properties of these wires.
Application
E-Mobility, hybrid constructions
Standards
IEC / DIN EN 60317-58
NEMA MW 84-C
Delivery forms
Grade 1: on request
Grade 2: on request
You have questions according to our winding wires or want to send an inquiry?
Our sales representative will be happy to help you.
Technical data
Typical properties of enamelled flat copper wire 5.60 x 3.55 mm, with insulation film grade 2.
Property | Unit of measure | Set value | Actual value (typ.) |
---|---|---|---|
Bare wire width | mm | 5.550-5.650 | as set value |
Bare wire thickness | mm | 3.500-3.600 | as set value |
Width with varnish | mm | 5.67-5.82 | as set value |
Thickness with varnish | mm | 3.62-3.77 | as set value |
Varnish increase | μm | 120-170 | as set value |
Adhesion (no cracks in film after winding) | mandrel diameter | mandrel diameter | |
Bend over width | 4 x width | 3 x width | |
Bend over thickness | 4 x thickness | 3 x thickness | |
Elongation | 15 % with cracks <1 x width | 32 % without cracks | |
Pencil hardness | H | 4H - 5H | |
Elongation at break | % | ≥ 32 | ≥ 38 |
Property | Unit of measure | Set value | Actual value (typ.) |
---|---|---|---|
Temperature index TI | °C | 220 | 220 |
Heat shock at 240 °C (no cracks in varnish coat after winding) | mandrel diameter 6 x thickness | mandrel diameter 4 x thickness | |
Solderability | no | no |
Property | Unit of measure | Set value | Actual value (typ.) |
---|---|---|---|
Dielectrical strength at RT | kV | ≥ 2.0 (ball pit) | ≥ 3 (ball pit) |
High voltage discontiniuties test voltage 2,5 kV | / | ≤ 7 on 100 m | |
Electrical conductivity | MS/m | 58-59 | ≥ 58.5 |
Property | Set value | Actual value (typ.) |
---|---|---|
Pencil hardness (storage in standard solvent ½ h / 60 °C) | min. H | 3H - 5H |
Pencil hardness (storage in alcohol ½ h / 60 °C) | min. H | 3H - 5H |
Resistance to commercial impregnants^(1) | yes | yes |
Resistance to commercial refrigerants^(1) | / | yes |
Resistance to commercial dry transformer oils^(1) | / | yes |
Resistance to commercial hydraulic oils^(1) | / | yes |