SynSleeve – Electrical Insulating Sleeves Textile Braided Sleeving H/GS
The H/GS sleeving is a textile braided sleeving with a polymer coating of silicone-elastomer.
H/GS is flexible, non-transparent and available in natural as standard colour (other colours on request). The textile braided sleeving ensures very good mechanical properties even at very high temperatures up to class H (180 °C) and short-term up to 230 °C.
Application
The H/GS sleeving is generally used as mechanical protection for cables and enamelled copper wires if very high thermal resistance is required. It offers additional insulation in electrical machines and electrical engineering equipment in the low voltage range as well as in some electronic applications.
Standards
Thermal class H (180 °C)
DIN EN 60684-3 sheet 401:2002
Delivery forms
Standard: natural up to ID 20
Special colours available on request.
0.5 – 2.0 mm 200 m
2.0 – 3.5 mm 100 m spool
4.0 – 10.0 mm 100 m cardboard core
11.0 – 16.0 mm 50 m cardboard core
from 16.0 mm - 1 m sections
Further formats, colours, dimensions on request. All dimensions can be delivered in adapted lengths.
You have questions according to our insulating or want to send an inquiry?
Our sales representative will be happy to help you.
Technical data
Property | Unit of measure | |||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inner diameter (ID) | mm | 0.3 | 0.5 | 0.8 | 1.0 | 1.5 | 2.0 | 2.5 | 3.0 | 4.0 | 5.0 | 6.0 | 8.0 | 10.0 | 12.0 | 16.0 |
Tolerance (ID) | mm | + 0.10 | + 0.20 | + 0.20 | + 0.40 | + 0.40 | + 0.40 | + 0.40 | + 0.40 | + 0.50 | + 0.50 | + 0.50 | + 0.50 | + 1.00 | + 1.00 | + 2.00 |
Wall thickness (wt) min. | mm | 0.15 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.20 | 0.30 | 0.30 | 0.30 | 0.30 | 0.40 | 0.40 | 0.40 |
Wall thickness (wt) max. | mm | 0.30 | 0.50 | 0.50 | 0.60 | 0.60 | 0.70 | 0.70 | 0.70 | 0.70 | 0.70 | 0.70 | 1.00 | 1.00 | 1.20 | 1.20 |
Property | Unit of measure | Values |
---|---|---|
Thermal class | °C | H (180) |
Application range | °C | -45 up to 230 |
Property | Unit of measure | Values | Test method |
---|---|---|---|
Insulation resistance | Ω | min. 10^5 | DIN EN 60684 |
Dielectric strength | kV | min. 4 | DIN EN 60684-sheet 401 |