SynSleeve – Electrical Insulating Sleeves Extruded Sleeving H
Sleeving H is an extruded silicone sleeving.
Sleeving H is flexible, transparent and available in various colours. Due to the silicone rubber coating, this sleeving provides high permanent temperature resistance of class H (180 °C) and thermal resistance up to 200 °C; the special quality version guarantees thermal resistance up to 250 °C.
Application
Sleeving H is used as lightweight, additional mechanical protection for applications with very high thermal stress. Furthermore, it offers additional electrical insulation for cables and enamelled copper wires in electric machines and transformers as well as in certain electronic applications.
Standards
According DIN 60684-3, sheet 123:2001
Delivery forms
Standard: transparent (inner diameter / ID 5)
Special colours on request:
Red, blue, white, black (ID5) and green (ID2)
Length in m on a cardboard ring:
0.3 - 2.0 mm 200 m rings/ cardboard spools
2.5 - 3.5 mm 100 m rings/ cardboard spools
4.0 - 9.0 mm 100 m rings
10.0 mm 50 m rings
14.0 - 30.0 mm on request
All dimensions can be delivered in adapted lengths.
You have questions according to our insulating or want to send an inquiry?
Our sales representative will be happy to help you.
Technical data
Property | Unit of measure | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inner diameter (ID) | mm | 0.3 | 0.5 | 0.8+ | 1.0 | 1.5 | 2.0 | 2.5 | 3.0 | 4.0 | 5.0 | 6.0 | 8.0 | 10.0 | 12.0 | 16.0 | 20.0 | 25.0 | 30.0 |
Tolerance (ID) | mm | +0.10/-0.05 | +0.15/-0.10 | +0.15/-0.10 | +0.20/-0.15 | +0.20/-0.15 | +0.20/-0.15 | +0.20/-0.20 | +0.20/-0.20 | +0.20/-0.20 | +0.20/-0.20 | +0.25/-0.25 | +0.25/-0.25 | +0.25/-0.25 | +0.25/-0.25 | +0.50/-0.50 | +0.50/-0.50 | +0.50/-0.50 | +0.50/-0.50 |
Property | Unit of measure | |||||||
---|---|---|---|---|---|---|---|---|
Wall thickness (wt) nominal | mm | 0.20 | 0.50 | 0.40 | 0.70 | 1.0 | 1.5 | 2.0 |
Tolerance (wt) | mm | -0.05/+0.15 | 0.05/0.15 | -0.05/+0.15 | -0.05/+0.15 | -0.05/+0.15 | -0.20/+0.20 | -0.20/+0.20 |
Property | Unit of measure | Values | Test method |
---|---|---|---|
Elongation at break | % | 500 (min. 200) | DIN EN 60684 |
Tear force | MPa | 11 (min. 5.5) | DIN EN 60684 |
Property | Unit of measure | Values |
---|---|---|
Thermal class | °C | 180 |
Application range | °C | -60 up to 200 (special version up to 250) |
Property | Unit of measure | Conditions | Values | Test method |
---|---|---|---|---|
Dielectric strength | kV | appr. 1 / 0.1 mm wall thickness | DIN EN 60684 | |
Specific volume resistance | Ω*cm | room temperature | min. 10^11 | DIN EN 60684 |
Property | Values |
---|---|
Resistance | weather, ozone, UV |