SynChem – Resins & Varnishes Damisol® 3500 LoV 1-component-resin

Damisol® 3500 LoV is a Freon resistant heat curing epoxy resin with low viscosity.

Damisol® 3500 LoV has the following properties:

  • low viscosity
  • Freon resistant
  • very low VOC emission
  • suitable for dipping- and vacuum-impregnating processes
  • excellent long-term heat resistance
Download datasheet

Application

Damisol® 3500 LoV is mainly used for the impregnation of medium and low voltage industrial motors. Due to the very good electrical, mechanical and thermal properties of Damisol® 3500 LoV it is also suitable for traction motors and transformers.

Standards

  • Thermal class H (UL 1446) / E98511

Delivery forms

Damisol® 3500 LoV is available in:

  • 20 kg cans
  • 200 kg drums
  • 1000 kg container

Storage

Damisol® 3500 LoV can be stored 12 months in sealed containers at room temperature (max. 25 °C). Higher temperature can be reached during short period of time. If storing the resin in a supply tank, dry air or "Nitrogen" is recommended. Protect from light, sun and heat.

Hardening

The curing time is 2.5 h at 170 °C. The exact curing time depends on different parameters.

Protection

Please avoid contact of Damisol® 3500 LoV with skin. Use safety gloves and glasses.

Please refer to the material safety data sheet for complete information.

Processing

The most commonly used processes are atmospheric impregnation and vacuum pressure impregnation (VPI). However, the good stability of the resin also allows processing at elevated temperatures (dipping, rolling and trickling processes). With the "hot dipping process", the engine can be heated up to 90 °C before impregnation.

Find your right resins and varnishes with us!

You have questions according to our resins and varnishes or want to send an inquiry?
Our product manager will be happy to help you.

Dr. Dimitri Jung

Productmanager
+49 5235-968-235 d.jung@synflex.de

Get in touch now.

Technical data

Mechanical
Property Unit of measure Condition Values Test method
Gel time min at 130 °C 12±3 gel norm 20g
Glass transition temperature °C 122 IEC 61006
Water absorption % after 24h at 23 °C ≤ 0.3 ISO 62 (method 1)
Bond strength daN at 180 °C 8.3 IEC 1033
Electrical
Property Unit of measure Condition Values Test method
Dielectric strength at 23 °C and 50 % r.h. kV/mm 159 DIN 46448/VDE 0360
Dielectric strength at 23 °C after 96 h storage at 92 % r.h. kV/mm 143 DIN 46448/VDE 0360
Dielectric loss factor % at 25 °C tan delta < 1 IEC 60250
Dielectric loss factor % at 105 °C tan delta ≤ 2 IEC 60250
Dielectric loss factor % 130 °C tan delta ≤ 5.5 IEC 60250
Chemical
Property Unit of measure Condition Values test method
Resistance % transformer oil < 0.1 ISO 175
Resistance % chemicals HCI 10 % ≤ 0.14 ISO 175
Liquid phase
Property Unit of measure Condition Values test method
Colour yellowish
Flashpoint °C ≥100 ISO 3679
Viscosity mPas at 25 °C 600 ± 200 ISO 2884-1
VOC acc. 31. BlmSchV % < 2 IEC 60455-3