SynChem – Resins & Varnishes Damisol® 3418 API 1-component-resin
Damisol® 3418 API is a one component class H high voltage epoxy resin.
Damisol® 3418 API has the following properties:
- no VOC (Volatile Organic Compound)
- low viscosity
- high thermal and chemical resistance
- high dielectric properties
- suitable for API market
Application
Damisol® 3418 API can be used on any kind of high voltage equipment. The maximum voltage will depend on process possibilities. On rotating machines, the resin is mainly used up to 15 kV in combination with the Mica tape. It is particularly suitable for harsh environment like oil and gas industry (API-compliance).
Standards
- VOC-free acc. 2010/75/EU
- Temperature index 200 °C -IEC 60216
Delivery forms
Damisol® 3418 API is available in
- 20 kg cans
- 230 kg drums
- 1100 kg container
Storage
Damisol® 3418 API 01 can be stored minimum 9 months at max. 25 °C in sealed containers, protected from light and sun. Higher temperature can be achieved during short period of time.
Hardening
Pre-heating of the oven to 120 °C is recommended.
Recommended curing time in 2 steps:
- 4 h at 120 °C
- 8 h at 160 °C
Protection
Refer to the material safety data sheet for complete information.
Processing
The low viscosity of this resin allows room temperature (20-25 °C) VPI impregnation. For high main wall insulation thickness, the motor temperature can achieve 60 °C (measured on steel) before impregnation. It is not recommended to perheat the resin.
It is recommended to use Nitrogen or dry air (Dew point -60 °C recommended) during the pressure phase. The storage tank has to be maintained under vacuum 5-10 mbars.
If regularly used, we recommend to maintain the resin temperature at room temperature (23 °C max.). If not used during a few days, in order to prolong its viscosity stability, it will have to be a cooled down to 15 °C (or lower). Nevertheless it is recommende to refresh regularly with new resin (at least 10 % of the storage tank volume per month). The resin has to protected from moisture, heat and contamination. A regular viscosity check is therefore necessary.
You have questions according to our resins and varnishes or want to send an inquiry?
Our product manager will be happy to help you.
Technical data
Property | Unit of measure | Conditions | Value | Test method |
---|---|---|---|---|
Viscosity | mPas | at 25 °C | 200-600 | ISO 2884 |
Gel time | min | at 135 °C, 12 g | 20-26 | |
Density | g/cm³ | at 23 °C | 1.15 |
Property | Unit of measure | Conditions | Value | Test method |
---|---|---|---|---|
Temperature index | °C | -10 % weight loss limit | 201 | IEC 60216 |
Glass transition temperature | °C | 136 | DMA |
Property | Unit of measure | Condition | Value | Test method |
---|---|---|---|---|
Water absorption | % | after 7 d at 23 °C | < 0.37 | ISO 62 |
Property | Unit of measure | Conditions | Value | Test method |
---|---|---|---|---|
Flashpoint | °C | >110 | ISO 3679 |