SynCon® – Connecting Cables & Transformer Terminals SynCon® TRKS 4, TRKSD 4 and TRKS 4/3
This type family has been developed for direct assembly on the coil body with integrated installation chambers. All terminals can also be snapped onto aluminium transformer rails 2 x 10 mm and 2 x 35 mm in size.
The type series includes:
- Single, double and triple terminals with screw connections
- Single, double and triple terminals
- Green/yellow PE terminals for screw connecting and welding to the core stack
- Fuse terminals for the relevant 5 x 20 mm, 5 x 30 mm and 6.3 x 32 mm cartridge fuse links
- Single, double and triple terminals with a connection capacity of 10 mm2
Technical drawing
![](/fileadmin/_processed_/d/d/csm_TRKS_4_d22d7e732e.jpg)
![](/fileadmin/_processed_/6/d/csm_TRKSD_4_efa4cf1fa1.jpg)
Delivery forms
50 units per package
![](/fileadmin/_processed_/4/a/csm_SofiaKoenig_c47a1276f1.png)
Find your right products with us!
You have questions according to our products or want to send an inquiry?
Our sales representative will be happy to help you.
Technical data
Technical data
Property | Unit of measure | TRKS 4 | TRKSD 4 | TRKS 4/3 |
---|---|---|---|---|
Design | single terminal | double terminal | triple terminal | |
Rated cross section | mm² | 4 | 4 | 4 |
Max. Strombelastbarkeit | A | 30 | 30 | 30 |
Rated voltage | V | only possible with transformer | only possible with transformer | only possible with transformer |
Rated insulation voltage | V | 690 | 690 | 690 |
Rated surge voltage / Contamination class | kV / - | 8 / 3 | 8 / 3 | 8/3 |
Surge voltage category/Insulation material group | III / I | III / I | III / I |
Nominal data acc. to CSA
Property | Unit of measure | TRKS 4 | TRKSD 4 | TRKS 4/3 |
---|---|---|---|---|
Rated voltage | V | 600 | 600 | 600 |
Nominal current | A | 27 | 27 | 30 |
AWG | kcmil | 24-10 | 24-10 | 18-12 |
Nominal data acc. to UL
Property | Unit of measure | TRKS 4 | TRKSD 4 | TRKS 4/3 |
---|---|---|---|---|
Rated voltage | V | 600 | 600 | 600 |
Nominal current | A | 30 | 30 | 30 |
AWG | kcmil | 30-10 | 30-10 | 30-10 |
Connection data
Property | Unit of measure | TRKS 4 | TRKSD 4 | TRKS 4/3 |
---|---|---|---|---|
Strand cross section rigid min | mm² | 0.2 | 0.2 | 0.2 |
Strand cross section rigid max | mm² | 6 | 6 | 6 |
Strand cross section flexible min | mm² | 0.2 | 0.2 | 0.2 |
Strand cross section flexible max | mm² | 4 | 4 | 4 |
Strand cross section with AEH min | mm² | 0.25 | 0.25 | 0.25 |
Strand cross section with AEH max | mm² | 1.5 | 1.5 | 1.5 |
2 strands equal cross section rigid min | mm² | 0.2 | 0.2 | 0.2 |
2 strands equal cross section rigid max | mm² | 1.5 | 1.5 | 1.5 |
2 strands equal cross section flexible min | mm² | 0.2 | 0.2 | 0.2 |
2 strands equal cross section flexible max | mm² | 1.5 | 1.5 | 1.5 |
2 strands equal cross section with TWIN-AEH min | mm² | 0.50 | 0.5 | 0.5 |
2 strands equal cross section with TWIN-AEH max | mm² | 2.5 | 2.5 | 2.5 |
Number of connections | 2 | 4 | 6 | |
Connection type | screw connection | screw connection | screw connection | |
Stripping length | mm | 8 | 8 | 8 |
Thread | M3 | M3 | M3 | |
Torque | Nm | 0.6-0.8 | 0.6-0.8 | 0.6-0.8 |
Material data
Property | TRKS 4 | TRKSD 4 | TRKS 4/3 |
---|---|---|---|
Insulation material | PA | PA | PA |
Inflammability class acc. to UL 94 | V2 | V2 | V2 |
Contact surface | tin-plated | tin-plated | tin-plated |
Description
Property | TRKS 4 | TRKSD 4 | TRKS 4/3 |
---|---|---|---|
Colour | TRKS 4 GY | TRKSD 4 GY | TRKSD 4/3 GY |
Colour | TRKS 4 OG | TRKSD 4 OG | TRKS 4/3 OG |