SynSleeve – Electrical Insulating Sleeves Textile Braided Sleeving H/GS SV6 UL
The H/GS SV6h UL-sleeving consists of a glass yarn with a polymer coating of silicone.
The H/GS SV6 UL sleeving is flexible, non-transparent and available in various colours. The glass fiber sleeving ensures very good mechanical properties at high temperatures up to class H (180 °C). It is applicable for temperature ranges between -60 and +250 °C. The sleeving shows a good resistance to UV as well as transformer oils and liquid fuels which do not lead to a decomposition. It is also halogen-free and watertight.
Standards
- Temperature class H (180°C)
- HL1, HL2 and HL3 acc. to railway standard DIN EN 45545
- In accordance with:
EN (CEI) 60684-3, sheet 400 to 402 (02/2003)
EN 60684-1 (10/2003)
EN 60684-2 (07/2012)
EN 60695-2-11 (09/2014) - Manufactured acc. to IEC standard
- Homologation UL 1441 / CSA C22.2 No. 198.3
Grade A silicone covered fiberglass sleeving
rated 200 °C, 600 V
file-no. UZFT2/8 - E468446 - Flamability class VW-1 for red (ID: 0.64 - 50 mm) and black (ID: 10 - 50 mm)
- Horizontal flamability for black (ID: <10 mm)
Delivery forms
Packaging:
0.5 mm: 400 m
0.8 to 1.5 mm: 300 m
2 to 6 mm: 200 m
7 to 12 mm: 100 m
13 to 20 mm: 50 m
22 to 25 mm: 25 m
26 to 50 mm: 30 m
Color
Standard colour: Black and brick red (other colours on request)
Technical data
Dimension
Property | Unit of measure | |||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inner diameter (ID) | mm | 0.5 | 0.8 | 1.0 | 1.5 | 2.0 | 2.5 | 3.0 | 3.5 | 4.0 | 5.0 | 6.0 | 7.0 | 8.0 | 9.0 | 10 | 12 | 14 | 16 | 18 | 20 | 22 | 25 | 30 | 35 | 40 | 45 | 50 |
Tolerance (ID) | mm | ± 0.10 | ± 0.10 | ± 0.20 | ± 0.20 | ± 0.20 | ± 0.20 | ± 0.20 | ± 0.20 | ± 0.25 | ± 0.25 | ± 0.25 | ± 0.25 | ± 0.25 | ± 0.50 | ± 0.50 | ± 0.50 | ± 0.50 | ±1 | ±1 | ±1 | ±1 | ±1 | ±1 | ±1 | ±1 | ±1 | ±1 |
Thermal
Property | Unit of measure | Values |
---|---|---|
Thermal class | °C | H (180) |
Application area | °C | -60 up to +250 |
Electrical
Property | Unit of measure | Values | Test method |
---|---|---|---|
Dielectric strength | kV | min. 7 | DIN EN 60684 |