SynSleeve – Electrical Insulating Sleeves Textile Braided Sleeving F/GS
The F/GS sleeving consists of a of a glass yarn sleeving with a polymer coating of PUR. .
The F/GS sleeving is flexible, non-transparent and available in various colours. The glass fabric sleeving ensures very good mechanical properties at high temperatures up to class F (155 °C). It is applicable for temperature ranges between -20 and +155 °C. It is resistant against chemicals, oils and lubricants.
Application
The F/GS sleeving is used as additional mechanical protection for connecting cables and winding wires at high temperatures and mechanical loads. It also provides additional insulation in electrical machines and transformers as well as in some electronic applications.
Standards
Thermal class F (155 °C)
In accordance with DIN EN 60684-3, sheet 409:1999
Delivery forms
Standard colour: natural - up to ID 30 mm.
Black up to ID 12
Yellow, green, red up to ID 6.
Special colours available on request.
0.5 – 2.0 mm 200 m
2.0 – 3.5 mm 100 m spool
4.0 – 10.0 mm 100 m cardboard core
11.0 – 16.0 mm 50 m cardboard core
From 14.0 mm - 1 m sections
Further formats and dimensions on request. All dimensions can be delivered in adapted lengths.
Technical data
Property | Unit of measure | |||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Inner diameter (ID) | mm | 0.5 | 0.8 | 1 | 1.5 | 2 | 2.5 | 3 | 3.5 | 4 | 4.5 | 5 | 6 | 7 | 8 | 9 | 10 | 12 | 14 | 16 |
Tolerance (ID) | mm | +0.30 | +0.40 | +0.40 | +0.40 | +0.40 | +0.40 | +0.50 | +0.50 | +0.50 | +0.50 | +0.50 | +0.50 | +0.50 | +0.60 | +0.60 | +0.60 | +0.60 | +1.00 | +1.00 |
Wall thickness (wt) nominal | mm | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 | 0.7 |
Tolerance (wt) | mm | ±0.15 | ±0.15 | ±0.15 | ±0.15 | ±0.15 | ±0.15 | ±0.15 | ±0.15 | ±0.15 | ±0.15 | ±0.15 | ±0.15 | ±0.15 | ±0.30 | ±0.30 | ±0.30 | ±0.30 | ±0.30 | ±0.30 |
Property | Unit of measure | ||||||
---|---|---|---|---|---|---|---|
Inner diameter (ID) | mm | 14 | 16 | 18 | 20 | 26 | 30 |
Tolerance (ID) | mm | ±0.5 | ±0.5 | ±0.5 | ±0.5 | ±0.6 | ±0.6 |
Wall thickness (wt) nominal | mm | 0.7 | 0.7 | 0.7 | 0.7 | 1.0 | 1.2 |
Tolerance (wt) | mm | ±0.30 | ±0.30 | ±0.30 | ±0.30 | ±0.50 | ±0.50 |
Property | Unit of measure | Values |
---|---|---|
Thermal class | °C | F (155) |
Application range | °C | -20 up to 155 |
Property | Unit of measure | Values | Test method |
---|---|---|---|
Dielectric strength | kV | min. 4 | DIN EN 60684 |