SynCon® Connecting Cables Single Core Conductor BETAtherm® 155 UL/cUL (metric)

BETAtherm® 155 UL/cUL is a flexible low-voltage cable with UL recognition, consisting of a tinned copper stranded wire and insulated with coloured electron-beam crosslinked polyolefine copolymer.

Due to its electron-beam cross-linked insulation, BETAtherm® 155 UL/cUL achieves a special thermal resistance required for Class F. This results in excellent thermal resistance. However, it cannot even be melted at elevated temperatures and has to be skinned during processing. Skinning is simple and also possible at machines.

BETAtherm® cables are resistant to common insulating varnishes. They are flame retardant.

Download datasheet

Application

BETAtherm® 155 UL/cUL is suitable for the internal wiring of electric machines, lamps, heating appliances, as well as for application in apparatus, mechanical and plant engineering.

Due to the high thermal load capacity, it might be possible to reduce the conductor cross section and, therefore, save space and reduce the weight.

Standards

  • Thermal class F (155 °C / UL-rating 150 °C)
  • RoHS compliant according to 2011/65 EC
  • UL AWM Style 3289, cUL CL 1503 (valid from 0.50 mm²)

Delivery forms

Metric dimensions

mm²

rings / m

4.0-10.0 100
16.0-25.0 50
35.0-95.0 25

 

Conductor

Tinned copper wire VDE 0295/ IEC 60228 class 5.

The dimensions specified in the technical datasheet are regarded as standard values. The actual cross sections may vary. The cables are manufactured according to European standards with a metric conductor cross section, AWG sizes are approximate values and viceversa.
Always observe relevant standards valid for divergent operating conditions when laying for greater limit current loads.

Color

Green-yellow, black, light blue, red, yellow, green.
Brown, white, grey, violet, orange and 2-coloured on request.

Technical data

Dimension
Property Unit of measure
Nominal cross section mm² 0.25 0.5 0.75 1.00 1.5 2.5 4 6 10 16 25 35 50 70 95 120
Strands x diameter mm 14 x 0.15 16 x 0.20 24 x 0.20 32 x 0.20 27 x 0.25 45 x 0.25 52 x 0.30 78 x 0.30 74 x 0.40 119 x 0.40 181 x 0.40 257 x 0.40 371 x 0.40 336 x 0.50 444 x 0.50 570x0.50
Cu Litz nom. diameter mm 0.65 0.90 1.15 1.25 1.55 2.05 2.55 3.10 4.10 5.0 6.20 7.70 9.70 11.20 12.8 14.6
Wall thickness desired mm 0.85 0.85 0.85 0.85 0.85 0.85 0.85 0.85 1.30 1.70 1.70 1.70 2.20 2.30 2.30 2.2
Wall thickness UL min mm 0.686 0.686 0.686 0.686 0.686 0.686 0.686 0.686 1.041 1.372 1.372 1.372 1.829 1.829 1.829 1.829
Outer diameter mm 2.35 ± 0.10 2.60 ± 0.10 2.85 ± 0.10 2.95 ± 0.10 3.25 ± 0.20 3.75 ± 0.20 4.25 ± 0.20 4.80 ± 0.20 6.70 ± 0.30 8.40 ± 0.30 9.60 ± 0.30 11.10 ± 0.40 14.10 ± 0.40 15.80 ± 0.40 17.40 ± 0.40 19.0 ± 0.40
Thermal load kWh/m 0.044 0.052 0.059 0.062 0.072 0.087 0.103 0.120 0.247 0.398 0.469 0.579 0.961 1.146 1.269 1.358
Mechanical
Property Values
Bend radius 4 x outer diameter
Soldering resistance very good
Thermal
Property Unit of measure Conditions Values Test method
Thermal class F
Temperature range fixed application °C -55 bis +150 UL 3289 / cUL 1503
Temperature range short circuit °C max. 5 sec. +280
Thermal resistance 155 °C / 5000 h IEC 60216-2
Burning behaviour flame retardent EN/IEC 60332-1-2
Chemical
Property Values
Insulation Polyolefine copolymer electron beam cross-linked
Resistance against resistant against common impregnants
Electrical
Property Unit of measure Conditions Values
Rated voltage V UO/U 600/1000 AC
Testing voltage V 50 Hz / 2 min. 3500